Supermarket & Retail Kitchens

V-Type Air-Cooled Condenser for Industrial Refrigeration Systems

  • Fresh
  • Durable
  • Customizable

The V-Type Air-Cooled Condenser uses angled heat-exchange coils and axial fan airflow to reject heat from refrigerant, offering multiple capacity configurations for commercial and industrial refrigeration systems.

  • Nominal Heat Rejection 24.84–165.60 kW (converted from source values listed in watts)
  • Heat Exchange Area 72–480 m²
  • Space-Efficient V-Shaped Coil Layout
  • Axial Fan Airflow
  • Multiple Capacity Options
  • Serviceable Coil and Fan Assembly
  • Flexible Installation
  • Chilled or Frozen Transport
  • Portable Design
  • Power Flexibility
V-Type Air-Cooled Condenser for Industrial Refrigeration Systems Get a Quote
Overview

A V-Shaped Condenser Designed for Efficient Heat Rejection

A V-Type Air-Cooled Condenser is a heat-rejection component used in refrigeration systems. Its two angled coil sections form a V-shaped arrangement, while axial fans drive ambient air through the heat-exchange surfaces. This configuration can provide a substantial coil area within a compact footprint. The correct model should be selected according to the required heat rejection, refrigerant operating conditions, local ambient temperature, airflow needs and available installation space.

View Specifications
Containerized cold room being crane-lifted onto a concrete base at a distribution site
  • V-Shaped Heat-Exchange Arrangement

    The two angled coil banks create a V-shaped profile that accommodates heat-exchange surface area within a compact structure. The arrangement can help reduce the footprint required for a given equipment configuration.

  • Forced-Air Heat Transfer

    Axial fans move ambient air across the finned coil surfaces. Heat passes from the refrigerant through the coil wall and fins to the surrounding air, allowing the refrigerant vapor to condense when the system operates within its design conditions.

  • Finned Coil Construction

    The product information describes grooved copper tubes and hydrophilic aluminium fins. The tube-and-fin assembly provides a heat-transfer path between the refrigerant and airflow. Confirm materials and construction details for the selected model before publishing final specifications.

  • Flexible Fan Configurations

    The published models use one to four fans, with listed fan diameters from 500 mm to 710 mm. Total airflow and fan power vary by model, so selection should be based on the actual operating point rather than fan count alone.

  • Capacity Range for Project Selection

    The source table lists heat rejection values from 24,840 W to 165,600 W. Converted to kilowatts, these values correspond to approximately 24.84–165.60 kW. These figures should be treated as source-listed ratings until the manufacturer confirms the test conditions and rating basis.

  • Applications in Refrigeration and Cooling

    V-type air-cooled condensers may be considered for compatible commercial refrigeration, industrial refrigeration and chiller applications. Confirm refrigerant compatibility, operating conditions, electrical requirements and installation clearances before specifying the equipment.

Specifications

Technical Specifications

Reference configuration for the two standard sizes. Dimensions, refrigeration capacity and electrical supply are confirmed for each project in the quotation drawing.

Model

Heat Rejection (kW)*

Heat Exchange Area (m²)

Fan Diameter (mm)

Fan Qty.

Airflow (m³/h)

Static Pressure (Pa)

Fan Power (W)

Voltage (V)

Inlet Pipe Dia. (mm)

Outlet Pipe Dia. (mm)

Dimensions L × W × H (mm)

Mounting L × W (mm)

LV25/72-551

24.84

72

550

1

7,400

80

670

380

22

16

950 × 900 × 890

870 × 650

LV30/87-601

30.102

87

600

1

9,100

80

825

380

25

16

1100 × 1000 × 870

1020 × 650

LV39/110-502

39.05

110

500

2

2 × 5300

60

2 × 449

380

25

16

1400 × 900 × 890

1320 × 650

LV45/130-552

44.85

130

550

2

2 × 7400

80

2 × 670

380

28

19

1550 × 900 × 890

1470 × 650

LV55/155-552

55.025

155

550

2

2 × 7400

80

2 × 670

380

28

19

1600 × 1000 × 980

1520 × 750

LV64/185-602

63.825

185

600

2

2 × 9100

80

2 × 825

380

28

22

1700 × 1000 × 1085

1620 × 750

LV73/210-632

72.66

210

630

2

2 × 9900

80

2 × 937

380

32

22

2200 × 1000 × 1185

2120 × 750

LV83/240-553

82.80

240

550

3

3 × 7400

80

3 × 670

380

32

22

2470 × 1000 × 980

2390 × 750

LV93/270-603

93.42

270

600

3

3 × 9100

80

3 × 825

380

35

25

2710 × 1000 × 980

2630 × 750

LV104/300-633

103.80

300

630

3

3 × 9900

80

3 × 937

380

35

25

2710 × 1000 × 1080

2630 × 750

LV111/320-633

111.04

320

630

3

3 × 9900

80

3 × 937

380

38

25

2890 × 1000 × 1080

2810 × 750

LV125/360-713

124.56

360

710

3

3 × 12650

80

3 × 1494

380

42

28

2890 × 1175 × 1120

2810 × 925

LV138/400-634

138.40

400

630

4

4 × 9900

80

4 × 937

380

42

28

3530 × 1000 × 1080

3450 × 750

LV166/480-714

165.60

480

710

4

4 × 12650

80

4 × 1494

380

54

28

3770 × 1175 × 1120

3690 × 925

Configurations

Configured Around
What You Store

Choose the temperature version first, then add the upgrades your site and product need. Every option is built and tested in the factory, not retrofitted on site.

  • 0 → +15 °C

    Chilled Storage

    Fruit, vegetables, flowers, dairy and beverages — humidity-friendly air distribution.

    01
  • −18 → −25 °C

    Frozen Storage

    Meat, seafood, ice cream and frozen food, with heated door frames and pressure relief.

    02
  • Down to −40 °C

    Blast Freezer

    High-capacity unit and airflow for fast pull-down of fresh product to core temperature.

    03
  • Chill + Freeze

    Dual-Zone Room

    An insulated partition splits a 40HQ into two rooms, each with its own refrigeration.

    04
For an Accurate Quotation, Please Provide:

Based on this information, the cold storage box and refrigeration configuration can be matched to the buyer’s vehicle and operating conditions.

  • Required internal or external box dimensions
  • Required storage temperature
  • Type of products to be transported
  • Vehicle type and cargo area dimensions
  • Required quantity
  • Available power supply
  • Daily operating time
  • Local ambient temperature
  • Required battery or solar configuration
Applications

Where It Works Best

The Portable Cold Storage Box for Tricycles, Vans & Pickup Trucks is suitable for transporting and storing temperature-sensitive products such as:

How We Deliver

From Inquiry to Cold Storage

  1. 01

    Requirement Review

    Product, target temperature, daily loading and site power supply.

  2. 02

    Design & Quotation

    Heat-load calculation, layout drawing and a configured quotation.

  3. 03

    Production & Testing

    Built in our factory and pull-down tested before it is released.

  4. 04

    Shipping & Documents

    Ships as a standard container with export and customs paperwork.

  5. 05

    Start-Up Support

    Remote commissioning guidance and long-term spare parts supply.

FAQ

Frequently Asked Questions

  • What is a V-type air-cooled condenser?

    A V-type air-cooled condenser uses two angled coil sections arranged in a V-shaped profile. Fans move ambient air across the coil surfaces to reject heat from refrigerant in a compatible refrigeration system.

  • What heat-rejection capacities are available?

    The source table lists values from 24,840 W to 165,600 W, equivalent to approximately 24.84–165.60 kW. Confirm the official rating basis and operating conditions before selecting a model.

  • How many fans are available across the series?

    The listed configurations use one, two, three or four axial fans. Fan diameter, airflow and power depend on the selected model.

  • What materials are used in the heat exchanger?

    The product information describes copper tubes and hydrophilic aluminium fins. Buyers should confirm the exact tube and fin specifications for the selected model.

  • What information is needed for model selection?

    Provide refrigerant type, required heat rejection, condensing temperature, design ambient temperature, electrical supply, piping connections and available installation space.

Start Your Project

Tell Us What You Store.
We'll Engineer the Cold.

Send your storage temperature, room size and location — our engineers reply with a configured solution and quotation within 24 hours.

  • Free Equipment Selection
  • Custom System Design
  • Response Within 24 h