Supermarket & Retail Kitchens

V-Type Air-Cooled Condenser for Commercial and Industrial Refrigeration

  • Fresh
  • Durable
  • Customizable

The V-Type Air-Cooled Condenser combines a V-arranged finned heat-exchange coil with axial fans to reject refrigerant heat, with multiple capacity configurations for refrigeration systems.

  • Nominal Heat Rejection Capacity 35–147 kW across the listed models
  • Heat-Exchange Area 120–500 m² across the listed models
  • V-Arranged Heat-Exchange Coil
  • Axial Fan-Assisted Airflow
  • Multiple Capacity Configurations
  • Defined Connection and Mounting Data
  • Flexible Installation
  • Chilled or Frozen Transport
  • Portable Design
  • Power Flexibility
V-Type Air-Cooled Condenser for Commercial and Industrial Refrigeration Get a Quote
Overview

V-Type Condenser Design for Refrigeration Heat Rejection

A V-type air-cooled condenser rejects heat from refrigerant by transferring it through a finned coil to ambient air. The V-arranged coil and axial fan configuration provide a practical equipment layout for refrigeration systems that require forced-air heat rejection. The published model range includes different heat-rejection capacities, heat-exchange areas, fan quantities, airflow rates and pipe connection sizes. For reliable equipment selection, the condenser should be matched to the refrigerant, condensing conditions, ambient temperature, electrical supply and installation layout of the project.

View Specifications
Containerized cold room being crane-lifted onto a concrete base at a distribution site
  • V-Shaped Coil Configuration

    The heat-exchange coil is arranged in a V-shaped structure, as shown in the source product diagram. This arrangement organizes the coil surface and fan assembly within a defined footprint. Confirm the precise overall layout and service clearances for the chosen model.

  • Forced-Air Heat Transfer

    Axial fans provide airflow across the finned coil to help transfer heat from the refrigerant to the surrounding air. The source table lists fan diameters of 500 mm, 550 mm or 630 mm, with two to four fans depending on model.

  • Capacity and Heat-Exchange Area Options

    Published heat-rejection values range from 35 kW to 147 kW, while the listed heat-exchange area ranges from 120 m² to 500 m². These figures are source-listed specifications; verify the rated operating conditions before using them for final equipment sizing.

  • Fan Power and Electrical Supply

    The source table lists 380 V for the models shown, with fan power depending on fan quantity and configuration. Confirm frequency, phase, motor current, control method and electrical protection requirements using the selected model’s approved nameplate and wiring diagram.

  • Refrigerant Pipe Connections

    The table specifies inlet and outlet pipe diameters by model. The listed values should be checked against the project’s piping standard and the manufacturer’s connection drawings before procurement or installation.

  • Installation and Maintenance Access

    Allow adequate clearance around the coil and fan discharge, provide a suitable supporting structure, and keep access available for coil cleaning and fan maintenance. Follow the manufacturer’s approved installation instructions and safety procedures.

Specifications

Technical Specifications

Reference configuration for the two standard sizes. Dimensions, refrigeration capacity and electrical supply are confirmed for each project in the quotation drawing.

Model

Heat Rejection (kW)

Heat-Exchange Area (m²)

Fan Qty.

Fan Diameter (mm)

Airflow (m³/h)

Fan Power (W)

Voltage (V)

Inlet Pipe (mm)

Outlet Pipe (mm)

Overall Dimensions L / D / B / H (mm)

Mounting Dimensions D × E (mm)

LFNV-35/120

35

120

2

500

2 × 6,500

2 × 420

380

22

16

1520 / 900 / 760 / 1450

1450 × 700

LFNV-41/140

41

140

2

550

2 × 7,500

2 × 550

380

25

16

1550 / 1000 / 860 / 1480

1480 × 800

LFNV-47/160

47

160

2

550

2 × 7,500

2 × 550

380

25

16

1740 / 1000 / 860 / 1670

1670 × 800

LFNV-53/180

53

180

2

550

2 × 7,500

2 × 550

380

28

19

1740 / 1000 / 960 / 1670

1670 × 800

LFNV-58/200

58

200

2

630

2 × 10,800

2 × 850

380

28

19

1920 / 1000 / 960 / 1850

1850 × 800

LFNV-64/220

64

220

2

630

2 × 10,800

2 × 850

380

28

22

2050 / 1000 / 1060 / 1980

1980 × 800

LFNV-70/240

70

240

2

630

2 × 10,800

2 × 850

380

32

22

2050 / 1000 / 1060 / 1980

1980 × 800

LFNV-83/280

83

280

3

550

3 × 7,500

3 × 550

380

32

22

2600 / 1000 / 960 / 2530

2530 × 800

LFNV-88/300

88

300

3

550

3 × 7,500

3 × 550

380

35

25

2540 / 1000 / 1060 / 2470

2470 × 800

LFNV-94/320

94

320

3

630

3 × 10,800

3 × 850

380

38

25

2660 / 1000 / 1060 / 2590

2590 × 800

LFNV-105/360

105

360

3

630

3 × 10,800

3 × 850

380

42

28

3000 / 1000 / 1060 / 2930

2930 × 800

LFNV-117/400

117

400

3

630

3 × 10,800

3 × 850

380

42

28

3000 / 1080 / 1160 / 2930

2930 × 876

LFNV-147/500

147

500

4

630

4 × 10,800

4 × 850

380

54

28

3660 / 1080 / 1160 / 3590

3590 × 876

Configurations

Configured Around
What You Store

Choose the temperature version first, then add the upgrades your site and product need. Every option is built and tested in the factory, not retrofitted on site.

  • 0 → +15 °C

    Chilled Storage

    Fruit, vegetables, flowers, dairy and beverages — humidity-friendly air distribution.

    01
  • −18 → −25 °C

    Frozen Storage

    Meat, seafood, ice cream and frozen food, with heated door frames and pressure relief.

    02
  • Down to −40 °C

    Blast Freezer

    High-capacity unit and airflow for fast pull-down of fresh product to core temperature.

    03
  • Chill + Freeze

    Dual-Zone Room

    An insulated partition splits a 40HQ into two rooms, each with its own refrigeration.

    04
For an Accurate Quotation, Please Provide:

Based on this information, the cold storage box and refrigeration configuration can be matched to the buyer’s vehicle and operating conditions.

  • Required internal or external box dimensions
  • Required storage temperature
  • Type of products to be transported
  • Vehicle type and cargo area dimensions
  • Required quantity
  • Available power supply
  • Daily operating time
  • Local ambient temperature
  • Required battery or solar configuration
Applications

Where It Works Best

The Portable Cold Storage Box for Tricycles, Vans & Pickup Trucks is suitable for transporting and storing temperature-sensitive products such as:

How We Deliver

From Inquiry to Cold Storage

  1. 01

    Requirement Review

    Product, target temperature, daily loading and site power supply.

  2. 02

    Design & Quotation

    Heat-load calculation, layout drawing and a configured quotation.

  3. 03

    Production & Testing

    Built in our factory and pull-down tested before it is released.

  4. 04

    Shipping & Documents

    Ships as a standard container with export and customs paperwork.

  5. 05

    Start-Up Support

    Remote commissioning guidance and long-term spare parts supply.

FAQ

Frequently Asked Questions

  • What is a V-type air-cooled condenser?

    It is a refrigeration heat-rejection unit that uses a V-arranged finned coil and fan-driven ambient airflow to transfer heat from refrigerant to the surrounding air.

  • What heat-rejection range is listed?

    The source table lists models from 35 kW to 147 kW. Actual performance depends on the refrigerant and the specified condensing and ambient conditions.

  • How many fans does the V-type condenser use?

    The listed configurations use two, three or four axial fans, with diameters of 500 mm, 550 mm or 630 mm depending on the model.

  • What electrical supply is shown?

    The source table lists 380 V for the displayed models. Confirm frequency, phase, rated current, wiring and protection requirements with the manufacturer.

  • What information is needed for model selection?

    Provide refrigerant type, required heat rejection, condensing temperature, design ambient temperature, electrical supply, piping requirements and available installation space.

Start Your Project

Tell Us What You Store.
We'll Engineer the Cold.

Send your storage temperature, room size and location — our engineers reply with a configured solution and quotation within 24 hours.

  • Free Equipment Selection
  • Custom System Design
  • Response Within 24 h