Supermarket & Retail Kitchens

U-Type Air-Cooled Condenser for Refrigeration Systems

  • Fresh
  • Durable
  • Customizable

The U-Type Air-Cooled Condenser combines a compact cabinet, axial fan ventilation and a heat-exchange assembly to support heat rejection in compatible refrigeration systems.

  • Fan configuration 1–2 axial fans across the listed models
  • Heat exchange area 42–130 m² across the listed models
  • Compact Cabinet Layout
  • Axial Fan Airflow
  • Multiple Model Options
  • Service Access Panels
  • Flexible Installation
  • Chilled or Frozen Transport
  • Portable Design
  • Power Flexibility
U-Type Air-Cooled Condenser for Refrigeration Systems Get a Quote
Overview

A Compact U-Type Condenser for Refrigeration Heat Rejection

A condenser removes heat from refrigerant during the refrigeration cycle. This cabinet-style U-type condenser combines a heat-exchange assembly with axial fans to move ambient air through the unit. Its compact housing and multiple model configurations can be considered for refrigeration projects where footprint, airflow and service access must be coordinated. Final selection should be based on verified ratings and actual refrigerant operating conditions.

View Specifications
Containerized cold room being crane-lifted onto a concrete base at a distribution site
  • Cabinet-Style Construction

    The cabinet encloses the heat-exchange assembly and provides a defined equipment footprint. Its panel layout helps organize the unit for installation and routine access.

  • Axial Fan Ventilation

    Axial fans move air through the heat-exchange section. Airflow and fan performance should be assessed against required heat rejection and site ambient conditions.

  • Heat-Exchange Surface

    The published table lists heat-exchange areas from 42 m² to 130 m². Surface area is one factor in condenser selection and should not be used alone to infer cooling capacity.

  • Model-Specific Fan Options

    The listed models use one or two fans, with fan diameters from 450 mm to 550 mm. Airflow, fan power and static pressure vary by model and should be confirmed against approved technical data.

  • Service and Maintenance Access

    Hinged cabinet panels provide access for inspection and service. Allow suitable working clearance and follow the manufacturer’s maintenance instructions.

  • Refrigeration System Applications

    The unit may be considered for compatible commercial or industrial refrigeration systems. Confirm refrigerant compatibility, rated conditions and required heat rejection before specifying it.

Specifications

Technical Specifications

Reference configuration for the two standard sizes. Dimensions, refrigeration capacity and electrical supply are confirmed for each project in the quotation drawing.

Model

Heat Removal at Δt=15 K (Source Value; Unit to Verify)

Heat Exchange Area (m²)

Fan Dia. (mm)

Fans

Airflow (m³/h)

Static Pressure (Pa)

Fan Power (W)

Voltage (V)

Inlet Pipe Dia. (mm)

Outer Pipe Dia. (mm)

Dimensions L × W × H (mm)

Mounting L × W (mm)

LUB15/42-501

15036

42

500

1

5600

60

449

380

19

16

900 × 770 × 710

610 × 870

LUB18/50-551

17950

50

550

1

5600

80

670

380

22

16

900 × 770 × 920

610 × 870

LUB21/60-551

21360

60

550

1

5600

80

449

380

22

16

900 × 770 × 920

610 × 870

LUB25/70-551

24640

70

550

1

5600

80

670

380

22

16

900 × 770 × 1020

610 × 870

LUB28/80-452

28240

80

450

2

2 × 4100

60

2 × 290

380

22

16

1330 × 850 × 910

900 × 820

LUB31/90-502

30500

90

500

2

2 × 5300

80

2 × 449

380

22

16

1330 × 950 × 910

900 × 920

LUB35/100-502

35400

100

500

2

2 × 5300

80

2 × 449

380

22

16

1330 × 950 × 1010

900 × 920

FNU-39/110

39050

110

500

2

2 × 5300

80

2 × 449

380

22

16

1480 × 950 × 1010

1050 × 920

FNU-42/120

42240

120

550

2

2 × 7400

80

2 × 670

380

19

19

1730 × 1050 × 1020

1300 × 1020

FNU-46/130

46028

130

550

2

2 × 7400

80

2 × 670

380

19

19

1730 × 1050 × 1020

1300 × 1020

Configurations

Configured Around
What You Store

Choose the temperature version first, then add the upgrades your site and product need. Every option is built and tested in the factory, not retrofitted on site.

  • 0 → +15 °C

    Chilled Storage

    Fruit, vegetables, flowers, dairy and beverages — humidity-friendly air distribution.

    01
  • −18 → −25 °C

    Frozen Storage

    Meat, seafood, ice cream and frozen food, with heated door frames and pressure relief.

    02
  • Down to −40 °C

    Blast Freezer

    High-capacity unit and airflow for fast pull-down of fresh product to core temperature.

    03
  • Chill + Freeze

    Dual-Zone Room

    An insulated partition splits a 40HQ into two rooms, each with its own refrigeration.

    04
For an Accurate Quotation, Please Provide:

Based on this information, the cold storage box and refrigeration configuration can be matched to the buyer’s vehicle and operating conditions.

  • Required internal or external box dimensions
  • Required storage temperature
  • Type of products to be transported
  • Vehicle type and cargo area dimensions
  • Required quantity
  • Available power supply
  • Daily operating time
  • Local ambient temperature
  • Required battery or solar configuration
Applications

Where It Works Best

The Portable Cold Storage Box for Tricycles, Vans & Pickup Trucks is suitable for transporting and storing temperature-sensitive products such as:

How We Deliver

From Inquiry to Cold Storage

  1. 01

    Requirement Review

    Product, target temperature, daily loading and site power supply.

  2. 02

    Design & Quotation

    Heat-load calculation, layout drawing and a configured quotation.

  3. 03

    Production & Testing

    Built in our factory and pull-down tested before it is released.

  4. 04

    Shipping & Documents

    Ships as a standard container with export and customs paperwork.

  5. 05

    Start-Up Support

    Remote commissioning guidance and long-term spare parts supply.

FAQ

Frequently Asked Questions

  • What is a U-type condenser?

    A U-type condenser refers to a condenser design described by the source as using a U-shaped configuration. Confirm the exact coil arrangement and official English designation against the engineering drawing for the selected model.

  • What heat-exchange areas are available?

    The source table lists heat-exchange areas from 42 m² to 130 m². Final selection should consider rated heat rejection, refrigerant, condensing temperature and ambient conditions.

  • How many fans are used?

    The listed models use one or two axial fans. Fan diameter ranges from 450 mm to 550 mm, depending on the model.

  • What electrical supply is listed?

    The source table lists 380 V. Confirm phase, frequency, motor rating and electrical configuration with the manufacturer.

  • What information is needed for model selection?

    Provide refrigerant type, required heat rejection, condensing temperature, design ambient temperature, electrical supply, piping requirements and installation space.

Start Your Project

Tell Us What You Store.
We'll Engineer the Cold.

Send your storage temperature, room size and location — our engineers reply with a configured solution and quotation within 24 hours.

  • Free Equipment Selection
  • Custom System Design
  • Response Within 24 h