Supermarket & Retail Kitchens

U-Type Air-Cooled Condenser for Commercial and Industrial Refrigeration

  • Fresh
  • Durable
  • Customizable

The U-type air-cooled condenser uses a finned refrigerant coil and fan-driven airflow to release heat to ambient air, with multiple model options for refrigeration systems.

  • Nominal Motor Power Rating (HP) 3–40 HP across the listed models
  • Heat-Exchange Area 26–210 m² across the listed models
  • U-Type Coil Arrangement
  • Fan-Assisted Heat Rejection
  • Multiple Model Sizes
  • Model-Specific Connection and Footprint Data
  • Flexible Installation
  • Chilled or Frozen Transport
  • Portable Design
  • Power Flexibility
U-Type Air-Cooled Condenser for Commercial and Industrial Refrigeration Get a Quote
Overview

U-Type Condenser Design for Refrigeration Heat Rejection

A U-type air-cooled condenser rejects heat from refrigerant by transferring it through a finned coil to ambient air. Fan-driven airflow supports the condensation process when the unit operates within its specified design conditions. The published LFNU model range includes different heat-exchange areas, fan configurations, airflow figures, motor power ratings and connection sizes. To select a suitable condenser, buyers should consider the refrigerant, required heat rejection, condensing conditions, ambient temperature, electrical supply and available installation space.

View Specifications
Containerized cold room being crane-lifted onto a concrete base at a distribution site
  • U-Type Heat-Exchange Layout

    The product drawing shows a U-type coil arrangement within a framed condenser structure. This configuration groups the heat-transfer coil and fan assembly into one equipment package. Confirm the final footprint and access requirements using the selected model drawing.

  • Fan Configuration and Airflow

    The source table lists fan blade designations such as 4D400, 4D450, 4D500, 4D550, 4D600 and 4D630. Airflow figures vary by model and should be interpreted alongside the fan quantity and rating conditions listed in the confirmed datasheet.

  • Range of Heat-Exchange Areas

    The published heat-exchange area spans from 26 m² to 210 m². Coil area is one factor in heat transfer; refrigerant type, condensing temperature, ambient conditions, airflow and coil construction also affect actual performance.

  • Motor and Electrical Requirements

    The original table includes horsepower ratings and fan power information. Confirm the exact motor power, voltage, frequency, phase, current and control method from the selected model’s nameplate and wiring diagram before procurement.

  • Refrigerant Pipe Connections

    The source table lists inlet and outlet pipe diameters for each model. Confirm the diameter convention and connection type with the manufacturer, and check compatibility with the system piping design.

  • Installation and Routine Maintenance

    Provide a stable supporting base, unobstructed airflow and safe access for coil cleaning and fan servicing. Follow the manufacturer’s installation instructions and electrical safety requirements.

Specifications

Technical Specifications

Reference configuration for the two standard sizes. Dimensions, refrigeration capacity and electrical supply are confirmed for each project in the quotation drawing.

Model

Motor Rating (HP)

Heat-Exchange Area (m²)

Fan Qty.

Fan Blade Designation

Airflow (m³/h)

Power (W)

Inlet Pipe (mm)

Outlet Pipe (mm)

Overall A (mm)

Overall B (mm)

Overall C (mm)

Mounting D (mm)

Mounting E (mm)

LFNU-10/28

3

26

1

4D400

3920

180

22

10

630

590

715

423

545

LFNU-12/33

4

35

1

4D400

3920

180

22

10

680

630

715

473

585

LFNU-15/42

5

45

1

4D450

5415

250

19

12

680

670

870

473

625

LFNU-18/50

6

55

1

4D550

8920

600

19

12

900

710

870

633

665

LFNU-25/70

8

70

1

4D600

2 × 3920

780

25

19

1150

735

920

940

690

LFNU-28/80

10

80

1

4D600

11000

1 × 180*

25

19

1000

840

1130

633

794

LFNU-31/90

10

82

2

4D450

2 × 5415

2 × 250

25

19

1410

760

920

940

715

LFNU-35/100

12

100

2

4D500

2 × 7395

2 × 414

28

19

1410

810

920

940

765

LFNU-42/120

15

120

2

4D500

2 × 7395

2 × 414

28

19

1410

810

910

940

765

LFNU-140

20

140

2

4D550

2 × 8920

2 × 600

28

22

1510

810

1030

940

765

LFNU-170

25

170

2

4D600

2 × 11000

2 × 780

35

25

1560

855

1130

940

810

LFNU-190

30

190

2

4D600

2 × 11000

2 × 780

35

25

1560

855

1230

940

810

LFNU-210

40

210

2

4D630

2 × 12420

2 × 800

35

25

1560

855

1330

940

810

Configurations

Configured Around
What You Store

Choose the temperature version first, then add the upgrades your site and product need. Every option is built and tested in the factory, not retrofitted on site.

  • 0 → +15 °C

    Chilled Storage

    Fruit, vegetables, flowers, dairy and beverages — humidity-friendly air distribution.

    01
  • −18 → −25 °C

    Frozen Storage

    Meat, seafood, ice cream and frozen food, with heated door frames and pressure relief.

    02
  • Down to −40 °C

    Blast Freezer

    High-capacity unit and airflow for fast pull-down of fresh product to core temperature.

    03
  • Chill + Freeze

    Dual-Zone Room

    An insulated partition splits a 40HQ into two rooms, each with its own refrigeration.

    04
For an Accurate Quotation, Please Provide:

Based on this information, the cold storage box and refrigeration configuration can be matched to the buyer’s vehicle and operating conditions.

  • Required internal or external box dimensions
  • Required storage temperature
  • Type of products to be transported
  • Vehicle type and cargo area dimensions
  • Required quantity
  • Available power supply
  • Daily operating time
  • Local ambient temperature
  • Required battery or solar configuration
Applications

Where It Works Best

The Portable Cold Storage Box for Tricycles, Vans & Pickup Trucks is suitable for transporting and storing temperature-sensitive products such as:

How We Deliver

From Inquiry to Cold Storage

  1. 01

    Requirement Review

    Product, target temperature, daily loading and site power supply.

  2. 02

    Design & Quotation

    Heat-load calculation, layout drawing and a configured quotation.

  3. 03

    Production & Testing

    Built in our factory and pull-down tested before it is released.

  4. 04

    Shipping & Documents

    Ships as a standard container with export and customs paperwork.

  5. 05

    Start-Up Support

    Remote commissioning guidance and long-term spare parts supply.

FAQ

Frequently Asked Questions

  • What is a U-type air-cooled condenser?

    It is a refrigeration heat-rejection unit that uses a finned coil and fan-driven ambient airflow to transfer heat from refrigerant to the surrounding air.

  • What range of motor ratings is shown?

    The source table lists model ratings from 3 HP to 40 HP. Confirm whether the rating refers to the associated refrigeration unit or another specified motor rating before comparing models.

  • What heat-exchange area options are available?

    The visible table lists heat-exchange areas from 26 m² to 210 m². The final model should be selected based on the system load and verified operating conditions.

  • What should be checked before selecting a model?

    Confirm refrigerant type, required heat rejection, condensing and ambient temperatures, electrical supply, pipe connections, installation dimensions and maintenance clearances.

  • Are airflow and power values the same for every model?

    No. The source table shows different fan configurations, airflow values and power entries. Use the confirmed model datasheet to verify these values for the selected configuration.

Start Your Project

Tell Us What You Store.
We'll Engineer the Cold.

Send your storage temperature, room size and location — our engineers reply with a configured solution and quotation within 24 hours.

  • Free Equipment Selection
  • Custom System Design
  • Response Within 24 h