Supermarket & Retail Kitchens

Industrial Air Cooled Condenser for Commercial and Industrial Refrigeration

  • Fresh
  • Durable
  • Customizable

Raxlyn air cooled condensers use optimized heat-exchanger coils, configurable fan systems and durable cabinets to reject heat efficiently for commercial refrigeration, cold rooms and industrial refrigeration projects.

  • Heat exchanger Copper tubes with aluminum fins
  • Fan options Standard AC or EC motors
  • Efficient Heat Transfer
  • Flexible System Matching
  • Options for Demanding Environments
  • Hot-Climate Configuration
  • Flexible Installation
  • Chilled or Frozen Transport
  • Portable Design
  • Power Flexibility
Industrial Air Cooled Condenser for Commercial and Industrial Refrigeration Get a Quote
Overview

Air Cooled Condensers Built for Reliable Refrigeration Performance

An air cooled condenser rejects heat from refrigerant to the surrounding air, allowing the refrigeration cycle to continue. Its performance depends on coil design, fan airflow, ambient temperature, refrigerant conditions and the compressor system it serves. Raxlyn provides configurable condenser solutions for commercial refrigeration, cold rooms and industrial applications, with options for coil rows, fan quantity, motor type, corrosion protection and refrigerant circuit layout. Final selection should be based on the project’s calculated heat-rejection requirement and the operating conditions specified by the system designer.

View Specifications
Containerized cold room being crane-lifted onto a concrete base at a distribution site
  • Optimized Copper-Tube and Aluminum-Fin Coil

    The condenser uses a finned coil design with copper tubes and aluminum fins. Mechanical tube expansion improves contact between the tubes and fins, supporting effective heat transfer from the refrigerant to the airflow. Coil rows and surface area should be selected according to the required duty and design conditions.

  • Fan Systems for Different Project Needs

    Standard AC fan motors and EC fan motor options are available according to configuration. Fan quantity and arrangement can be adapted to capacity, available installation space, airflow needs and project noise considerations.

  • Corrosion Protection Options

    For coastal or humid environments, epoxy-coated aluminum fins and nano surface treatments may be specified where available. Stainless-steel structural options can also be considered for selected applications. The appropriate protection level depends on airborne contaminants, humidity, cleaning practices and the installation environment.

  • Designed for High Ambient Conditions

    Outdoor condensers in hot climates need sufficient heat-transfer area and airflow to maintain suitable condensing conditions. High-ambient configurations can be considered for elevated ambient temperatures, including projects approaching 50°C when the selected model is specifically rated for those conditions.

  • Compatible with Multiple Compressor Arrangements

    The product range can be configured for scroll condensing units, semi-hermetic compressor units, screw compressor systems and parallel compressor systems. The condenser must be matched to the refrigerant, compressor operating envelope, required heat rejection and system controls rather than selected by nominal capacity alone.

  • Factory Quality Control and Export Support

    Manufacturing checks may include incoming-material inspection, coil assembly, pressure testing, fan operation checks and final inspection according to the production specification. For export projects, confirm packing method, shipping dimensions, documentation requirements and installation conditions before dispatch.

Specifications

Technical Specifications

Reference configuration for the two standard sizes. Dimensions, refrigeration capacity and electrical supply are confirmed for each project in the quotation drawing.

Item

Published Feature / Option

Application

Commercial refrigeration, small and medium cold rooms, condensing units, industrial refrigeration

Heat Exchanger

Copper tubes with aluminum fins

Tube-to-Fin Assembly

Mechanical tube expansion

Fan Motor

Standard AC motor; EC motor option

Coil Configuration

Different coil rows available

Fan Configuration

Different fan quantities and arrangements available

Corrosion Protection

Epoxy-coated aluminum fins and nano surface treatment options

Structure / Materials

Cabinet structure options; stainless-steel structure subject to configuration

Refrigerant Circuit

Customized circuit layouts available

High-Ambient Design

Available by configuration; verify rated ambient conditions for the selected model

Capacity / Performance

Confirm model-specific heat-rejection capacity, airflow, power, dimensions and operating conditions

Configurations

Configured Around
What You Store

Choose the temperature version first, then add the upgrades your site and product need. Every option is built and tested in the factory, not retrofitted on site.

  • 0 → +15 °C

    Chilled Storage

    Fruit, vegetables, flowers, dairy and beverages — humidity-friendly air distribution.

    01
  • −18 → −25 °C

    Frozen Storage

    Meat, seafood, ice cream and frozen food, with heated door frames and pressure relief.

    02
  • Down to −40 °C

    Blast Freezer

    High-capacity unit and airflow for fast pull-down of fresh product to core temperature.

    03
  • Chill + Freeze

    Dual-Zone Room

    An insulated partition splits a 40HQ into two rooms, each with its own refrigeration.

    04
For an Accurate Quotation, Please Provide:

Based on this information, the cold storage box and refrigeration configuration can be matched to the buyer’s vehicle and operating conditions.

  • Required internal or external box dimensions
  • Required storage temperature
  • Type of products to be transported
  • Vehicle type and cargo area dimensions
  • Required quantity
  • Available power supply
  • Daily operating time
  • Local ambient temperature
  • Required battery or solar configuration
Applications

Where It Works Best

The Portable Cold Storage Box for Tricycles, Vans & Pickup Trucks is suitable for transporting and storing temperature-sensitive products such as:

How We Deliver

From Inquiry to Cold Storage

  1. 01

    Requirement Review

    Product, target temperature, daily loading and site power supply.

  2. 02

    Design & Quotation

    Heat-load calculation, layout drawing and a configured quotation.

  3. 03

    Production & Testing

    Built in our factory and pull-down tested before it is released.

  4. 04

    Shipping & Documents

    Ships as a standard container with export and customs paperwork.

  5. 05

    Start-Up Support

    Remote commissioning guidance and long-term spare parts supply.

FAQ

Frequently Asked Questions

  • Which refrigeration systems can use a Raxlyn air cooled condenser?

    It can be configured for scroll condensing units, semi-hermetic compressor units, screw compressor systems and parallel compressor systems. The final match depends on refrigerant, operating conditions and required heat rejection.

  • What materials are used in the heat exchanger?

    The published standard design uses copper tubes and aluminum fins assembled with mechanical tube expansion. Confirm any alternative materials with the supplier for the selected model.

  • Are EC fan motors available?

    EC fan motor options are listed among the available configurations. Confirm motor type, control method, electrical data and availability for the required model.

  • Can the condenser be used in coastal or humid environments?

    Corrosion-protection options such as epoxy-coated aluminum fins and nano surface treatment may be available. Suitability depends on the site environment and the selected protection specification.

  • Can it operate at an ambient temperature of 50°C?

    High-ambient tropical designs are described as an available option, but a 50°C rating should not be assumed for every model. Request performance data at the project’s actual design ambient temperature.

Start Your Project

Tell Us What You Store.
We'll Engineer the Cold.

Send your storage temperature, room size and location — our engineers reply with a configured solution and quotation within 24 hours.

  • Free Equipment Selection
  • Custom System Design
  • Response Within 24 h