The compressor raises refrigerant pressure and temperature. The condenser releases heat to ambient air, the expansion valve reduces refrigerant pressure, and the evaporator absorbs heat from the water circuit.
Fans move ambient air through the condenser coil. The airflow carries heat away as the refrigerant condenses. Adequate ventilation and clearance around the unit help support stable operation.
In the evaporator, heat moves from circulating water to the refrigerant. The cooled water can then be supplied to compatible process equipment or other cooling loads.
Model selection should account for cooling load, water temperatures, flow rate, ambient design conditions, power supply, and installation space. These inputs help avoid choosing an undersized or unsuitable unit.
Install the chiller on a suitable foundation with sufficient airflow and service access. Routine inspection of the condenser coil, fans, water circuit, electrical connections, and safety controls helps maintain reliable operation.
Reference configuration for the two standard sizes. Dimensions, refrigeration capacity and electrical supply are confirmed for each project in the quotation drawing.
Model
Specification
FNa02-4850
Rated 48.45 V; 50 Ah cell / 50 Ah rated; 2.422 kWh | Max. charge / discharge 50 / 100 A | Cycle life 8,000 cycles | Dimensions / weight 440 × 550 × 140 mm; 42.5 kg
FNa02-48100
Rated 48.45 V; 50 Ah cell / 100 Ah rated; 4.845 kWh | Max. charge / discharge 100 / 200 A | Cycle life 8,000 cycles | Dimensions / weight 560 × 800 × 140 mm; 80.5 kg
FNa02-48170
Rated 48.45 V; 170 Ah cell / 170 Ah rated; 8.236 kWh | Max. charge / discharge 150 / 200 A | Cycle life 8,000 cycles | Dimensions / weight 440 × 780 × 235 mm; 100.5 kg
The Portable Cold Storage Box for Tricycles, Vans & Pickup Trucks is suitable for transporting and storing temperature-sensitive products such as:
Product, target temperature, daily loading and site power supply.
Heat-load calculation, layout drawing and a configured quotation.
Built in our factory and pull-down tested before it is released.
Ships as a standard container with export and customs paperwork.
Remote commissioning guidance and long-term spare parts supply.
It transfers heat from circulating water to a refrigerant in the evaporator. The compressor circulates and raises the pressure of the refrigerant, and the air-cooled condenser releases the absorbed heat into ambient air.
No. It rejects heat through a condenser coil and fans, so a cooling tower is not required. The unit still needs suitable airflow and installation clearance.
Provide the required cooling capacity, water inlet and outlet temperatures, water flow rate, ambient design temperature, power supply, installation environment, and process details.
It may be suitable when its capacity, water temperatures, flow rate, and operating range match the application. Confirm these requirements with the supplier before ordering.
Maintenance commonly includes checking and cleaning the condenser coil, inspecting fan operation, checking water flow and strainers, reviewing electrical connections, and verifying safety controls in line with the manufacturer’s instructions.
Send your storage temperature, room size and location — our engineers reply with a configured solution and quotation within 24 hours.
Arabic
English
French
German
Indonesian
Italian
Portuguese
Russian
Spanish
Turkish
Vietnamese