Supermarket & Retail Kitchens

Evaporative Cooling Integrated Refrigeration Unit

  • Fresh
  • Durable
  • Customizable

An integrated refrigeration unit combining evaporative heat rejection, compressor equipment and electrical controls for industrial and commercial cooling projects.

  • Heat-Rejection Method Evaporative cooling with water spray and forced airflow
  • Control System PLC-based electrical control; confirm exact functions
  • Integrated Equipment Layout
  • Evaporative Heat Rejection
  • Intelligent Control Options
  • Industrial Application Potential
  • Flexible Installation
  • Chilled or Frozen Transport
  • Portable Design
  • Power Flexibility
Evaporative Cooling Integrated Refrigeration Unit Get a Quote
Overview

Integrated Evaporative Cooling for Industrial Refrigeration

An evaporative cooling integrated refrigeration unit uses water evaporation and forced airflow to assist heat rejection from the refrigeration circuit. By bringing key equipment and electrical controls together, an integrated design can simplify project coordination compared with sourcing each component separately. Suitability depends on the required cooling duty, local climate, water quality, operating schedule and maintenance plan. Buyers should review the unit-specific performance data and utility requirements before finalizing a system design.

View Specifications
Containerized cold room being crane-lifted onto a concrete base at a distribution site
  • How Evaporative Heat Rejection Works

    Water is sprayed or distributed over a heat-exchange surface, and airflow promotes evaporation. The latent heat absorbed during evaporation helps remove heat from the refrigerant circuit. Actual heat-rejection capacity varies with entering-air conditions, water distribution and equipment design.

  • Integrated Refrigeration Components

    The product images show an enclosed cabinet, compressor equipment and a control section. The exact component list may vary by model, so the quotation should identify the compressor, heat exchanger, fans, pumps, valves and accessories included in the supply.

  • PLC and Electrical Control

    The source material refers to PLC control, frequency conversion and sensor-based monitoring. These functions can support coordinated operation when included in the confirmed configuration. Verify control logic, alarm outputs, variable-speed devices and any remote monitoring options before purchase.

  • Water Management and Maintenance

    Evaporative equipment requires attention to water quality, scale, corrosion and biological growth. A suitable water-treatment and cleaning plan helps maintain heat-transfer performance. Confirm water consumption, blowdown requirements, filtration and recommended maintenance intervals with the supplier.

  • Site and Climate Suitability

    Evaporative heat rejection is influenced by local wet-bulb temperature, humidity, ventilation and water availability. The installation location should provide adequate airflow and service access. In water-restricted or highly humid environments, alternative heat-rejection arrangements may need evaluation.

  • Selection Based on Operating Conditions

    Do not select equipment based on the product name alone. Confirm cooling capacity at the intended operating point, refrigerant, evaporating and condensing conditions, electrical supply, water requirements, dimensions and noise data. A project-specific selection helps avoid mismatches between equipment and application.

Specifications

Technical Specifications

Reference configuration for the two standard sizes. Dimensions, refrigeration capacity and electrical supply are confirmed for each project in the quotation drawing.

Item

Information / Status

Product Category

Evaporative cooling integrated refrigeration unit

Heat-Rejection Principle

Evaporative cooling combined with forced ventilation, as described on the source page

Compressor Arrangement

Compressor equipment is shown; exact type, quantity and model require confirmation

Control System

PLC, frequency converter and sensors are mentioned in the source description; confirm the supplied configuration

Cooling Capacity

Not stated; request model-specific performance data

Refrigerant

Not stated clearly for this exact unit; confirm from the nameplate and datasheet

Rated Power / Electrical Supply

Not stated; confirm voltage, phase, frequency, current and total connected load

Water Consumption

Not stated numerically; obtain water flow, evaporation and blowdown data

Airflow / Fan Data

Not stated; confirm fan quantity, airflow and motor ratings

Dimensions / Weight

Not stated; request outline drawing and shipping specifications

Operating Limits

Not stated numerically; confirm ambient conditions and rated operating range

Materials / Corrosion Protection

Source text mentions corrosion-resistant materials; confirm actual casing and heat-exchanger materials

Configurations

Configured Around
What You Store

Choose the temperature version first, then add the upgrades your site and product need. Every option is built and tested in the factory, not retrofitted on site.

  • 0 → +15 °C

    Chilled Storage

    Fruit, vegetables, flowers, dairy and beverages — humidity-friendly air distribution.

    01
  • −18 → −25 °C

    Frozen Storage

    Meat, seafood, ice cream and frozen food, with heated door frames and pressure relief.

    02
  • Down to −40 °C

    Blast Freezer

    High-capacity unit and airflow for fast pull-down of fresh product to core temperature.

    03
  • Chill + Freeze

    Dual-Zone Room

    An insulated partition splits a 40HQ into two rooms, each with its own refrigeration.

    04
For an Accurate Quotation, Please Provide:

Based on this information, the cold storage box and refrigeration configuration can be matched to the buyer’s vehicle and operating conditions.

  • Required internal or external box dimensions
  • Required storage temperature
  • Type of products to be transported
  • Vehicle type and cargo area dimensions
  • Required quantity
  • Available power supply
  • Daily operating time
  • Local ambient temperature
  • Required battery or solar configuration
Applications

Where It Works Best

The Portable Cold Storage Box for Tricycles, Vans & Pickup Trucks is suitable for transporting and storing temperature-sensitive products such as:

How We Deliver

From Inquiry to Cold Storage

  1. 01

    Requirement Review

    Product, target temperature, daily loading and site power supply.

  2. 02

    Design & Quotation

    Heat-load calculation, layout drawing and a configured quotation.

  3. 03

    Production & Testing

    Built in our factory and pull-down tested before it is released.

  4. 04

    Shipping & Documents

    Ships as a standard container with export and customs paperwork.

  5. 05

    Start-Up Support

    Remote commissioning guidance and long-term spare parts supply.

FAQ

Frequently Asked Questions

  • What is an evaporative cooling integrated refrigeration unit?

    It is a refrigeration assembly that uses evaporative heat rejection and combines major equipment within an integrated arrangement. The exact components and capacity depend on the selected model.

  • How does evaporative cooling remove heat?

    Water evaporates from a wetted heat-exchange surface, absorbing heat, while fans move air to support the process. Performance depends on ambient wet-bulb temperature, airflow, water distribution and system design.

  • Can this unit be used for any industrial cooling project?

    Not automatically. The unit must be matched to the required cooling load, operating temperatures, climate, water availability, water quality and site conditions.

  • What water-related requirements should buyers check?

    Ask for water flow, water quality limits, filtration, blowdown, treatment recommendations and cleaning intervals. These factors affect maintenance and long-term heat-transfer performance.

  • Does the unit include PLC and variable-frequency control?

    The source description mentions PLCs, frequency converters and sensors, but the exact included functions are not specified. Confirm the control bill of materials and available features for the quoted model.

Start Your Project

Tell Us What You Store.
We'll Engineer the Cold.

Send your storage temperature, room size and location — our engineers reply with a configured solution and quotation within 24 hours.

  • Free Equipment Selection
  • Custom System Design
  • Response Within 24 h