The enclosed air-cooled condenser combines a finned heat-exchange coil, axial fans and a protective cabinet structure to reject refrigerant heat across multiple capacity configurations.

  • Nominal Heat Rejection 35–147 kW across the listed models
  • Heat Exchange Area 120–500 m² across the listed models
  • Protective Cabinet Structure
  • Fan-Driven Heat Rejection
  • Multiple Capacity Configurations
  • Model-Specific Piping and Mounting Dimensions
  • Flexible Installation
  • Chilled or Frozen Transport
  • Portable Design
  • Power Flexibility
Enclosed Air-Cooled Condenser for Commercial and Industrial Refrigeration Get a Quote
Overview

An Enclosed Condenser for Reliable Refrigeration Heat Rejection

An enclosed air-cooled condenser rejects heat from refrigerant by transferring it through a finned coil to ambient air. The VB-series product information shows a cabinet-style assembly with multiple axial fans and model-specific heat-exchange areas, piping connections and mounting dimensions. This format can help integrate the condenser into commercial or industrial refrigeration equipment layouts. The final model should be selected using verified heat-rejection ratings, refrigerant operating conditions, ambient temperature, airflow requirements, electrical data and available installation space.

View Specifications
Containerized cold room being crane-lifted onto a concrete base at a distribution site
  • Integrated Cabinet Design

    The cabinet combines the heat-exchange coil and fan assembly in a single equipment structure. Confirm enclosure material, corrosion protection and access-panel details for the exact configuration before specifying them in project documents.

  • Axial Fan Airflow

    The published models use two, three or four fans, with listed fan diameters of 500, 550 or 630 mm. Total airflow and fan power depend on the selected model and should be checked against the actual operating conditions.

  • Heat-Exchange Area Options

    The source table lists heat-exchange areas from 120 m² to 500 m². Coil area is one factor in heat-transfer performance; refrigerant conditions, ambient temperature, airflow and coil design also affect the actual capacity.

  • Capacity Range for System Planning

    Nominal heat rejection is listed from 35 kW to 147 kW. These values are transcribed from the source specification image and should be treated as published ratings until the manufacturer confirms the test conditions and rating basis.

  • Piping and Installation Dimensions

    The table provides inlet and outlet pipe diameters, overall dimensions and mounting dimensions. Use these values for preliminary planning only, and confirm the dimension order and connection definitions against the approved engineering drawing.

  • Application and Maintenance Considerations

    The condenser may be evaluated for compatible commercial refrigeration and industrial cooling systems. Provide unobstructed air intake and discharge, safe electrical access and sufficient clearance for coil cleaning and fan maintenance.

Specifications

Technical Specifications

Reference configuration for the two standard sizes. Dimensions, refrigeration capacity and electrical supply are confirmed for each project in the quotation drawing.

Model

Heat Rejection (kW)

Heat Exchange Area (m²)

Fan Qty.

Fan Diameter (mm)

Airflow (m³/h)

Fan Power (W)

Voltage (V)

Inlet Pipe (mm)

Outlet Pipe (mm)

Overall Dimensions L × D × H (mm)

Overall Dimension F (mm)

Mounting Dimensions D × E (mm)

LFNVB-35/120

35

120

2

500

2 × 6,500

2 × 420

380

22

16

1570 × 900 × 1600

Not specified

1530 × 700

LFNVB-41/140

41

140

2

550

2 × 7,500

2 × 550

380

25

16

1600 × 1000 × 1700

Not specified

1560 × 750

LFNVB-47/160

47

160

2

550

2 × 7,500

2 × 550

380

25

16

1790 × 1000 × 1700

Not specified

1750 × 750

LFNVB-53/180

53

180

2

550

2 × 7,500

2 × 550

380

28

19

1790 × 1000 × 1800

Not specified

1750 × 750

LFNVB-58/200

58

200

2

630

2 × 10,800

2 × 850

380

28

19

1970 × 1000 × 1800

Not specified

1930 × 750

LFNVB-64/220

64

220

2

630

2 × 10,800

2 × 850

380

28

22

2100 × 1000 × 1900

Not specified

2060 × 750

LFNVB-70/240

70

240

2

630

2 × 10,800

2 × 850

380

32

22

2100 × 1000 × 1900

Not specified

2060 × 750

LFNVB-83/280

83

280

3

550

3 × 7,500

3 × 550

380

32

22

2650 × 1000 × 1800

Not specified

2610 × 750

LFNVB-88/300

88

300

3

550

3 × 7,500

3 × 550

380

35

25

2590 × 1000 × 1900

Not specified

2550 × 750

LFNVB-94/320

94

320

3

630

3 × 10,800

3 × 850

380

38

25

2760 × 1000 × 1900

Not specified

2720 × 750

LFNVB-105/360

105

360

3

630

3 × 10,800

3 × 850

380

42

28

3100 × 1000 × 1900

Not specified

3060 × 750

LFNVB-117/400

117

400

3

630

3 × 10,800

3 × 850

380

42

28

3100 × 1080 × 2000

Not specified

3060 × 876

LFNVB-147/500

147

500

4

630

4 × 10,800

4 × 850

380

54

28

3760 × 1080 × 2000

Not specified

3720 × 876

Configurations

Configured Around
What You Store

Choose the temperature version first, then add the upgrades your site and product need. Every option is built and tested in the factory, not retrofitted on site.

  • 0 → +15 °C

    Chilled Storage

    Fruit, vegetables, flowers, dairy and beverages — humidity-friendly air distribution.

    01
  • −18 → −25 °C

    Frozen Storage

    Meat, seafood, ice cream and frozen food, with heated door frames and pressure relief.

    02
  • Down to −40 °C

    Blast Freezer

    High-capacity unit and airflow for fast pull-down of fresh product to core temperature.

    03
  • Chill + Freeze

    Dual-Zone Room

    An insulated partition splits a 40HQ into two rooms, each with its own refrigeration.

    04
For an Accurate Quotation, Please Provide:

Based on this information, the cold storage box and refrigeration configuration can be matched to the buyer’s vehicle and operating conditions.

  • Required internal or external box dimensions
  • Required storage temperature
  • Type of products to be transported
  • Vehicle type and cargo area dimensions
  • Required quantity
  • Available power supply
  • Daily operating time
  • Local ambient temperature
  • Required battery or solar configuration
Applications

Where It Works Best

The Portable Cold Storage Box for Tricycles, Vans & Pickup Trucks is suitable for transporting and storing temperature-sensitive products such as:

How We Deliver

From Inquiry to Cold Storage

  1. 01

    Requirement Review

    Product, target temperature, daily loading and site power supply.

  2. 02

    Design & Quotation

    Heat-load calculation, layout drawing and a configured quotation.

  3. 03

    Production & Testing

    Built in our factory and pull-down tested before it is released.

  4. 04

    Shipping & Documents

    Ships as a standard container with export and customs paperwork.

  5. 05

    Start-Up Support

    Remote commissioning guidance and long-term spare parts supply.

FAQ

Frequently Asked Questions

  • What is an enclosed air-cooled condenser?

    It is a refrigeration heat-rejection unit that uses a finned coil and fan-driven ambient airflow, with the main assembly housed in a cabinet-style structure.

  • What capacity range is listed for this series?

    The source table lists nominal heat rejection from 35 kW to 147 kW and heat-exchange areas from 120 m² to 500 m². Confirm the rating conditions with the manufacturer before selecting a model.

  • How many fans are used?

    The listed models use two, three or four axial fans, with diameters of 500 mm, 550 mm or 630 mm depending on the model.

  • What electrical supply is shown in the table?

    The source table lists 380 V. Confirm frequency, phase, motor wiring, rated current and control requirements for the selected model.

  • What information is needed for model selection?

    Provide refrigerant type, required heat rejection, condensing temperature, design ambient temperature, electrical supply, pipe connection sizes and installation space.

Start Your Project

Tell Us What You Store.
We'll Engineer the Cold.

Send your storage temperature, room size and location — our engineers reply with a configured solution and quotation within 24 hours.

  • Free Equipment Selection
  • Custom System Design
  • Response Within 24 h